Double Wall Containment Piping Systems

Asahi/America has been providing double containment piping systems to meet Environmental Protection Agency (EPA) standards for over 25 years. As the innovator and patent holder of many double containment specialty devices, Asahi/America is best equipped to help engineers and designers fabricate and install double containment piping systems.

Our systems are engineered to protect our eco-system from the dangers of exposed aggressive chemicals. Additionally, the EPA has directed the underground transport of hazardous materials be protected from release into the environment in its Standard 40 CFR, Part 280 & 281. In order to be in compliance, systems must:

  • Have at least manual leak detection for drainage systems
  • Have automated leak detection for pressurized systems
  • Be double contained
  • Have outer containment able to retain media transport for a minimum of 30 days

Double containment should be specified for more applications than regulated by the EPA. Hazardous chemicals should be protected from escape in areas where there are chemicals transported above work stations, or any other potential safety hazards due to exposure to the media.

Asahi/America has been the industry leader in engineered thermoplastic double contained piping systems for decades. Our systems have been successfully installed with confidence across a broad range of industries. Ranging in sizes from 1×2 to 16×20 and above, choosing Asahi/America provides maximum flexibility in system engineering and design. For the varying requirements of double containment, Asahi/America provides a variety of piping system options.

poly-flo-piping

Applications:

Installations with tight space constraints, water treatment facilities using multiple chemicals, outside applications – due to UV resistance; systems where thermal expansion & contraction are present

Pipes & Fittings:

1×1-1/2, 2×3, 4×6 (32mmx50mm, 63mmx90mm, 110mmx160mm)

Materials:

Advanced PE and PP-R

Applications:

Drainage applications, pressurized transfer lines, manufacturing, underground installations

Pipes & Fittings:

1×3 through 16×20

Materials:

Polypropylene, PVDF, & ECTFE (Halar®)

chem-prolok

Applications:

Sodium hypochlorite; Sulfuric acid concentrations less than 85%; Hydrochloric acid concentrations less than 37%

Pipes & Fittings:

1×3 to 12×16

Materials:

Advanced PE polyethylene (both inner & outer)

Fluid-Lok

Applications:

Environmental Protection

Pipes & Fittings:

1×3 through 18×24

Materials:

HDPE

Pro-Lok

Applications:

Water treatment, Wastewater treatment

Pipes & Fittings:

1/2×2 through 4×8

Materials:

PVC & CPVC

Fluid-lok-w-leak

Applications:

For use with:

Duo-Pro®, Chem Prolok™, Fluid-Lok®, Poly-Flo® double wall piping systems

Closure-Coupling

Applications:

For use with Duo-Pro® double containment piping systems.

Size Range:

3″ (90mm) – 8″ (200mm)

Materials:

Pro150, Pro45